Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Treatment of Atrophic Ridges with Titanium Mesh: A Retrospective Study Using 100% Mineralized Allograft and Comparing Dental Stone Versus 3D-Printed Models
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 39 , Issue 4
July/August 2019

Pages 491–500


Treatment of Atrophic Ridges with Titanium Mesh: A Retrospective Study Using 100% Mineralized Allograft and Comparing Dental Stone Versus 3D-Printed Models

Edgard El Chaar, DDS, MS/Adolf B. Urtula, DDS/Aiketrini Georgantza, DDS/Stephanie Cruz, DDS/Pooria Fallah-Abed, DDS/Alejandro Castaño, DDS/Thierry Abitbol, DMD, MSc/Michael M. Warner, MA


PMID: 31226186
DOI: 10.11607/prd.3733

This multicenter study retrospectively evaluated implant survival and bone growth in atrophic ridges that were augmented with titanium mesh and 100% mineralized solvent-dehydrated bone allografts (MSDBA). A secondary objective of this study was to evaluate differences in outcomes by diagnostic model type. Titanium mesh was shaped on a diagnostic wax-up of the patient’s jaw: Twenty-three patients (Group 1) had wax-ups on dental stone models, and 16 patients (Group 2) had wax-ups on models fabricated with three-dimensional (3D) printing technology. Clinical and histologic data were analyzed. The average bone gain ranged from 5.94 to 6.91 mm horizontally and 5.76 to 6.99 mm vertically and was not significantly different between the two model groups (P > .05). Implant survival was 100% after 18 to 48 months. Although model type had no significant influence on outcomes, 3D-printed models allowed for faster surgery and served as visual aids for patient education.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help